Prostar Kenika KCT UPS Mode Inverter Low Frequency PSW 1KW 2KW 3KW 6KW With Charger System Power - 3000W 48V
Aksesoris & Kabel

Prostar Kenika KCT UPS Mode Inverter Low Frequency PSW 1KW 2KW 3KW 6KW With Charger System Power - 3000W 48V

Rp 3.339.850
Kode SKU -274
Kategori Aksesoris & Kabel
Ketersediaan Stok Tersedia (2 unit)

From Prostar Company To Kenika Indonesia
Best inverter Low frekuensi Toroidal Inverter
KENIKA KCT 1kW 2kW 3kW 6kW 10kW,
Dipercaya Masyarakat Indonesia dengan kehandalannya
system Battery 12V / 24V / 48V / 96V

VARIAN : KENIKA LOW FREKUENSI

KENIKA KCT-1K12 1000w 12v
KENIKA KCT-1K24 1000W 24V
KENIKA KCT-2K12 2000W 12V
KENIKA KCT-2K24 2000W 24V
KENIKA KCT-3K24 3000W 24V
KENIKA KCT-3K48 3000W 48V
KENIKA KCT-6K48 6000W 48V
KENIKA KCT-10K96 10Kw 96v

Low-frequency Pure sinewave inverter with built-in smart battery charger allows for you to use your existing grid power to maintain a charge on your batteries. Great for your emergency battery backup for when the grid goes down with an unnoticeable transfer time of 8 milliseconds, or for use as a standalone off-grid system.


MODEL : KCT-Prostar kenikak

*AC INPUT
Voltage Range : 220VAC (+25%)
Frequency Range : 50/60Hz ± 2.5Hz

*OUTPUT
Rated Power: 1000/2000W/3000W/5000/10K
Instantaneous Power: 2000/4000/6000W/10K
Wave Form: Pure Sine Wave
Battery Efficiency: 83%
AC Efficiency: 93%
Output Voltage : 220VAC (AC Mode ± 10%, Battery Mode ± 5%)
Output Frequency: 50Hz/60Hz ± 0.5Hz (AC Mode ± 2.5Hz)
Transfer Time: 4ms/8ms Optional
USB Output : DC 5V/1A x1, 5V/2A x1 (Optional)

*CONNECTOR
Input/Output : Input & Output Terminals
Battery : Terminals

*BATTERY
Voltage: 12V/24V/48V/96V
Charging Current: 1-20A Adjustable

*LCD
Method : LCD+LED
Content: Input/Output Voltage, Battery Voltage, Battery Capacity, Load Capacity, Working Mode, Frequency


*PROTECTION
Battery Reversal: Optional
Output Short Circuit: AC Mode: Jump Fuse, Inverter Mode: Shut Down
Overload: If Overload 105%, Inverter will Alarm. If Overload 130%, Inverter will shut down in 10s. Once the inverter is off, it must be turned on manually.
High AC Voltage: Turn off AC, Turn to Inverter Mode Automatically
Low DC Voltage: Inverter will shut down automatically, Once the AC recover, Inverter will turn on and change automatically
Over Temperature: Inverter will alarm and turn off output but it will recover to normal state after cooling down

*ENVIRONMENT
Humidity : 15-93% (No Condensation)
Temperature : -10° ~ 50°C
Altitude : ≤ 3000m